Vortex Tube Panel Enclosure Coolers

Information | Specifications | FAQs | Applications | Dimensions |Accessories | Streamtek index page

Cabinet Cooler

 

 

APPLICATIONS

ADVANTAGES
  • Cooling electronic controls
  • Cooling machining operations
  • Setting hot melts
  • Cooling soldered parts
  • Cooling gas samples
  • Electronic component cooling
  • Cooling heat seals
  • Cooling environmental chambers
  • Quiet & Affordable
  • Stainless steel construction
  • Fast Installation
  • No moving parts
  • Compact/Lightweight
  • No fans or filters
  • No CFC's
  • Mounts through standard knockout
  • Stabilize temperature/humidity

 

  • Cooling with Panel Enclosure Coolers
    Using our extremely low-cost, reliable Vortex Tube, these Panel Enclosure Coolers will purge AND cool electronic/electrical enclosures with filtered air that's up to 45F colder than the compressed air supply. Built into the cooler is a relief valve that exhausts the hot air from the cabinet, while the cooler continues to supply clean cold air. Our Panel Enclosure Coolers are ideal for all NEMA 4 and NEMA 12 rated panels. They mount in minutes through a standard knockout.

How to determine size requirements of the Panel Enclosure Cooler
1. Determine the watts of heat generated inside the enclosure.
Watts x 3.41 = (W) Btu/hr.

2. Determine the area in square feetthat is exposed to the air, not including the top of the cabinet.
[ 2 x {Width} + 2 x {Depth} ] {Height} = (S) Square feet of cabinet

3. Determine the temperature difference between the desired internal temperature and the maximum expected external temperature. Now you can use the below chart to determine the Btu/hr./sq. ft., for this differential (B).

Temperature
Difference (F)
Btu/hr./sq. ft.
5
1.5
10
3.3
15
5.1
20
7.1
25
9.1
30
11.3
35
13.8
40
16.2

4. Determine the external heat load (H).
(S) x (W) = (H) Btu/hr.

5. Now take (W) and add (H) to get the total heat load or Btu/hr. refrigeration required to maintain desired temperature and choose the correct one using the chart below.

Back to Top of Page

 

NEMA 12 (IP52) Cabinet Panel Cooler Only
Model No.
Capacity Btu/hr.
Material
787.CC1208-1
550
Stainless 303
787.CC1215-1
1100
Stainless 303
787.CC1225-1
1800
Stainless 303
787.CC1230-1
2060
Stainless 303
787.CC1240-1
2800
Stainless 303


NEMA 12 (IP52) Cabinet Panel Cooler Systems - Continuous Operation
Model No.
Description
787.CC1208-2
NEMA 12 Panel Cooler System, Continuous Operation, 550 Btu/hr.
(Includes: cooling unit, filter, and cold air distribution kit)

787.CC1215-2
NEMA 12 Panel Cooler System, Continuous Operation, 1100 Btu/hr.
(Includes: cooling unit, filter, and cold air distribution kit)

787.CC1225-2
NEMA 12 Panel Cooler System, Continuous Operation, 1800 Btu/hr.
(Includes: cooling unit, filter, and cold air distribution kit)

787.CC1230-2
NEMA 12 Panel Cooler System, Continuous Operation, 2060 Btu/hr.
(Includes: cooling unit, filter, and cold air distribution kit)

787.CC1240-2
NEMA 12 Panel Cooler System, Continuous Operation, 2800 Btu/hr.
(Includes: cooling unit, filter, and cold air distribution kit)



NEMA 12 (IP52) Cabinet Panel Cooler Systems - With Thermostat Control
Model No.
Description
787.CC1208-3
NEMA 12 Panel Cooler System, with Thermostat Control, 550 Btu/hr.
(Includes: Cooling unit, thermostat, solenoid valve, filter and cold air distribution kit)

787.CC1215-3
NEMA 12 Panel Cooler System, with Thermostat Control, 1100 Btu/hr.
(Includes: Cooling unit, thermostat, solenoid valve, filter and cold air distribution kit)

787.CC1225-3
NEMA 12 Panel Cooler System, with Thermostat Control, 1800 Btu/hr.
(Includes: Cooling unit, thermostat, solenoid valve, filter and cold air distribution kit)

787.CC1230-3
NEMA 12 Panel Cooler System, with Thermostat Control, 2060 Btu/hr.
(Includes: Cooling unit, thermostat, solenoid valve, filter and cold air distribution kit)

787.CC1240-3
NEMA 12 Panel Cooler System, with Thermostat Control, 2800 Btu/hr.
(Includes: Cooling unit, thermostat, solenoid valve, filter and cold air distribution kit)









NEMA 4/4X (IP56) Cabinet Panel Cooler Only
Model No.
Capacity Btu/hr.
Material
787.CC408-1
550
Stainless 303
787.CC415-1
1100
Stainless 303
787.CC425-1
1800
Stainless 303
787.CC430-1
2060
Stainless 303
787.CC440-1
2800
Stainless 303

NEMA 4/4X (IP56) Cabinet Panel Cooler Systems - Continuous Operation
Model No.
Description
787.CC408-2
NEMA 4/4X Panel Cooler System, Continuous Operation, 550 Btu/hr.
(Includes: cooling unit, filter, and cold air distribution kit)

787.CC415-2
NEMA 4/4X Panel Cooler System, Continuous Operation, 1100 Btu/hr.
(Includes: cooling unit, filter, and cold air distribution kit)

787.CC425-2
NEMA 4/4X Panel Cooler System, Continuous Operation, 1800 Btu/hr.
(Includes: cooling unit, filter, and cold air distribution kit)

787.CC430-2
NEMA 4/4X Panel Cooler System, Continuous Operation, 2060 Btu/hr.
(Includes: cooling unit, filter, and cold air distribution kit)

787.CC440-2
NEMA 4/4X Panel Cooler System, Continuous Operation, 2800 Btu/hr.
(Includes: cooling unit, filter, and cold air distribution kit)


NEMA 4/4X (IP56) Cabinet Panel Cooler Systems - With Thermostat Control
Model No.
Description
787.CC408-3
NEMA 4/4X Panel Cooler System, with Thermostat Control, 550 Btu/hr.
(Includes: Cooling unit, thermostat, solenoid valve, filter and cold air distribution kit)

787.CC415-3
NEMA 4/4X Panel Cooler System, with Thermostat Control, 1100 Btu/hr.
(Includes: Cooling unit, thermostat, solenoid valve, filter and cold air distribution kit)

787.CC425-3
NEMA 4/4X Panel Cooler System, with Thermostat Control, 1800 Btu/hr.
(Includes: Cooling unit, thermostat, solenoid valve, filter and cold air distribution kit)

787.CC430-3
NEMA 4/4X Panel Cooler System, with Thermostat Control, 2060 Btu/hr.
(Includes: Cooling unit, thermostat, solenoid valve, filter and cold air distribution kit)

787.CC440-3
NEMA 4/4X Panel Cooler System, with Thermostat Control, 2800 Btu/hr.
(Includes: Cooling unit, thermostat, solenoid valve, filter and cold air distribution kit)


 

 




Mounting:
The Cabinet Panel Cooler must be vertically mounted, on a flat surface surface for all enclosure types. The Streamtek Cabinet Panel Cooler system is easy to install through a 1-1/8" diameter drilled hole or electrical knockout.

Humidity:
It's important to close off any openings and any vents that may bring in ambient air, especially in warm or hot high humidity environments. The relative humidity inside the enclosure stabilizes at 45% for all continuous operating Cabinet Panel Coolers.

Filtration:
All Cabinet Panel Cooler systems include an auto drain 5 micron dirt and water filter. This filter is imperative to prevent any accidental water flow into the enclosure. If oil is present in the compressed air supply, use an oil filter within at least .3 micron rating.

Environmental Considerations

NEMA 4/4X (IP56) - Designed for Electronic Control Panels - Splash resistant, oil-tight, and dust-tight for use in wash down environments as well as outdoor use. When the Panel Cooler is not operating a low pressure relief valve closes and seals to maintain the integrity of your NEMA 4 cabinet enclosure. Constructed of Stainless Steel (Type 303) for long life in wet environments.

NEMA 12 (IP52) - Cabinet Panel Coolers (oil-tight, dust-tight) are used in industrial environemnts where no liquids can come in contact with the unit. Constructed of Stainless Steel (Type 303) to withstand harsh corrosive environments.

NEMA 12 (IP52) - Dust, Oil, and Corrosion Resistant
Model No. Capacity Btu/hr. Cabpacity Kcal/hr. Air Consumption SCFM @ 80 PSI Air Consumption
SLPM @ 5.5 Bar
Sound Level
787.CC1208-1 550 139 8 226 67*
787.CC1215-1 1,100 277 15 425 73*
787.CC1225-1 1,800 454 25 708 74*
787.CC1230-1 2,060 519 30 849 74*
787.CC1240-1 2,800 706 40 1,132 80*


NEMA 4/4X (IP56) - Dust, Oil, Corrosion, and Splash Resistant
Model No. Capacity Btu/hr. Cabpacity Kcal/hr. Air Consumption SCFM @ 80 PSI Air Consumption
SLPM @ 5.5 Bar
Sound Level
787.CC408-1 550 139 8 226 67*
787.CC415-1 1,100 277 15 425 73*
787.CC425-1 1,800 454 25 708 74*
787.CC430-1 2,060 519 30 849 74*
787.CC440-1 2,800 706 40 1,132 80*
*With Optional Cold Muffler installed

 

Back to Top of Page


Frequently Asked Questions



1. Can I use a Vortex Tube to cool my electrical enclosure instead of the Cabinet Panel Cooler?
Yes, however there are clear-cut advantages to using the Cabinet Panel Cooler for this application.
  • Cabinet Panel Coolers have a pressure release valve to allow warm air from the electrical enclosure to escape the cabinet.
  • Cabinet Panel Coolers have been fine tuned to achieve maximum refrigeration; this cannot be adjusted. Vortex Tubes on the other hand can be adjusted by the user, leaving them open to poor operation and miss-adjustment.
  • Cabinet Panel Coolers have been engineered to reduce noise levels drastically from that of the sole Vortex Tube.

2. How to do I stop the solenoid valve from chattering?
A .002 microfarad capacitor can be wired across the leads on the thermostat to stop it from chattering. This chattering can sometimes occur by a very slow temperature change. The capacitor simply desensitizes the thermostat to stop the chattering effect. The Capacitor is available FREE OF CHARGE at special request.


3. What is the cooling capacity (BTU/Hr.) of your Cabinet Panel Coolers?
STREAMTEK manufactures Cabinet Panel Coolers which produces 550 – 2,800 BTU/Hr. from a single unit. If you require additional cooling, we have dual cooler units from 3,600 – 5,600 BTU/Hr.


4. How do I know which Cabinet Panel Cooler I should use?
It’s never been easier! Simply complete our Cabinet Cooling Sizing guide and fax it to us at +1(800)605-2442. An Application Engineer will contact you with a recommendation. If you wish to determine the size requirements yourself, click here for step-by-step instructions.


5. Can condensation occur within our control panels when using the Cabinet Panel Coolers?
No. The Cabinet Panel Cooler will purge warm/moist air from inside your enclosure. The cool air that is being injected into the cabinet will then start to pick up heat, which in-turn causes the humidity to drop. A continuous operation Cabinet Panel Cooler will keep the relative humidity at about 45%. It is imperative that all openings in your panel are closed off, as humidity from the ambient air could cause condensation within your panel.


6. Where should the Cabinet Panel Cooler and Thermostat be installed?
The Cabinet Panel Cooler must be installed at the top of the cabinet through standard knockout, and secured with locking nut. A thermostat at the top of the cabinet is best (but not required), as this is the hottest spot due to the rising hot air.


7. What is the material of construction of the Cabinet Panel Cooler?
Stainless Steel (Type 303) is the material of construction on ALL coolers. They are corrosion proof, long lasting, and the stainless provides the best cold temperature drop.



Cabinet Cooler


Back to Top of Page


SIDE VIEW
cabcoolers

 

Back to Top of Page


thermostat-solenoid-valve

Thermostat and Solenoid Valve:
Cabinet Panel Systems with thermostat control include a thermostat and solenoid valve. This combination will limit the flow of compressed air to only when cooling is needed.

Solenoid valve is rated 120V, 60 Hz or 110V, 50 Hz and are CSA Certified, UL Listed.

The Adjustable Thermostat is factory set at 95F (35C). It has a tolerance of +/- 2F (1C) of the desired temperature inside the enclosure. Rated 120V, 50/60 Hz and is CSA Certified, UL Recognized.

 

 

ul-listed
ul-recognized
Thermostat (top) and Solenoid Valve (bottom). Both rated 120V, 60Hz or 110V, 50Hz and are UL Listed, CSA Certified.  

cold-air-kit Cold Air Distribution Kit
The Cold Air Distribution Kit is used to direct the cold air flow for circulation, or to hot spots within your enclosure. Kit includes a flexible length of vinyl tubing, and rubber lined clips to hold the tubing in place.
Cold Air Distribution kit includes flexible vinyl tubing, and adhesive rubber protected clips to hold the tubing in place.  



Cabinet Panel Coolers - Accessories
Model No.
Description
787.CC000-T
Adjustable Thermostat
(The adjustable thermostat is factory set at 95F (35C). It will normally hold +/- 2F (1C) of the desired temperature setting. Rated 120V, 50/60 Hz and is CSA Certified, UL Recognized )

787.SLD00-1
Solenoid Valve
(120V, 50/60 Hz), 40 SCFM (1133 SLPM)

787.FTR00-3
Manual drain Filter
(Metal bowl, 27 SCFM (765 SLPM), 5 micron, 1/4" NPT.)

787.FTR01-4
Automatic drain Filter.
(Metal Bowl, 27 SCFM (765 SLPM), 5 micron, 1/4" NPT.)

787.FTR00-4
Automatic drain Filter
(Metal Bowl, 43 SCFM (1218 SLPM), 5 micron, 1/4" NPT.)




back to Top of Page

servicing the Canadian provinces of Newfoundland, Nova Scotia, New Brunswick, Prince Edward Island, Quebec, Ontario, Manitoba, Saskatchewan, Alberta ,British Columbia and the states of Alabama, Alaska, Arizona, Arkansas, California, Colorado, Connecticut, Delaware, Florida, Georgia, Hawaii, Idaho, Illinois, Indiana, Iowa, Kansas, Kentucky, Louisiana, Maine, Maryland, Massachusetts, Michigan, Minnesota, Mississippi, Missouri, Montana, Nebraska, Nevada, New Hampshire, New Jersey, New Mexico, New York, North Carolina, North Dakota, Ohio, Oklahoma, Oregon, Pennsylvania, Rhode Island, South Carolina, South Dakota, Tennessee, Texas, Utah, Vermont, Virginia, Washington, West Virginia, Wisconsin,Wyoming We can ship via UPS to Afghanistan , Aland Islands , Albania , Algeria , American Samoa , Andorra , Angola , Anguilla , Antigua & Barbuda , Argentina , Armenia , Aruba , Australia , Austria , Azerbaijan , Azores , Bahamas , Bahrain , Bangladesh , Barbados , Belarus , Belgium , Belize , Benin , Bermuda , Bhutan , Bolivia , Bonaire , Bosnia , Botswana , Brazil , British Virgin Isles , Brunei , Bulgaria , Burkina Faso , Burundi , Cambodia , Cameroon , Canada , Canary Islands , Cape Verde , Cayman Islands , Central African Republic , Chad , Chile , China , Colombia , Comoros , Congo , Cook Islands , Costa Rica , Croatia , Curacao , Cyprus , Czech Republic , Democratic Republic of Congo , Denmark , Djibouti , Dominica , Dominican Republic , Ecuador , Egypt , El Salvador , England , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Faeroe Islands , Fiji , Finland , France , French Guiana , French Polynesia , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Greenland , Grenada , Guadeloupe , Guam , Guatemala , Guernsey , Guinea , Guinea-Bissau , Guyana , Haiti , Holland , Honduras , Hong Kong , Hungary , Iceland , India , Indonesia , Iraq , Ireland , Israel , Italy , Ivory Coast , Jamaica , Japan , Jersey , Jordan , Kazakhstan , Kenya , Kiribati , Kosrae , Kuwait , Kyrgyzstan , Laos , Latvia , Lebanon , Lesotho , Liberia , Libya , Liechtenstein , Lithuania , Luxembourg , Macau , Macedonia (Fyrom) , Madagascar , Madeira , Malawi , Malaysia , Maldives , Mali , Malta , Marshall Islands , Martinique , Mauritania , Mauritius , Mayotte , Mexico , Micronesia , Moldova , Monaco , Mongolia , Montenegro , Montserrat , Morocco , Mozambique , N. Mariana Islands , Namibia , Nepal , Netherlands , Netherlands Antilles , New Caledonia , New Zealand , Nicaragua , Niger , Nigeria , Norfolk Island , Northern Ireland , Norway , Oman , Pakistan , Palau , Panama , Papua New Guinea , Paraguay , Peru , Philippines , Poland , Ponape , Portugal , Puerto Rico , Qatar , Reunion , Romania , Rota , Russia , Rwanda , Saba , Saipan , San Marino , Saudi Arabia , Scotland , Senegal , Serbia , Seychelles , Sierra Leone , Singapore , Slovakia , Slovenia , Solomon Islands , South Africa , South Korea , Spain , Sri Lanka , St. Barthelemy , St. Christopher , St. Croix , St. Eustatius , St. John , St. Kitts & Nevis , St. Lucia , St. Maarten , St. Martin , St. Thomas , St. Vincent/Grenadines , Suriname , Swaziland , Sweden , Switzerland , Syria , Tahiti , Taiwan , Tajikistan , Tanzania , Thailand , Timor Leste , Tinian , Togo , Tonga , Tortola , Trinidad & Tobago , Truk , Tunisia , Turkey , Turkmenistan , Turks & Caicos Islands , Tuvalu , Uganda , Ukraine , Union Island , United Arab Emirates , United Kingdom , United States , Uruguay, US Virgin Islands , Uzbekistan , Vanatu , Vatican City State , Venezuela , Vietnam , Virgin Gorda , Wales , Wallia & Futuna Islands , Western Samoa , Yap , Yemen , Zambia , Zimbabwe