VORTEX TUBES



What is a Vortex Tube?
The Vortex Tube is an effective, low cost solution to a wide variety of industrial spot cooling and process cooling needs. Compressed air is injected into the vortex tube, flows at a rate of up to 1,000,000 RPM towards the 'hot' end of the tube. Once this hot air reaches the end, a small amount is exhausted through a control valve. The rest of the air is forced backwards towards the other end and exits as 'cold' air. The Vortex Tube can decrease temperatures by ~115F (46C) and raise temperatures up by ~200F (93C) from the initial inlet air temperature.
vortextube

 

Which Vortex Tube will best suite my needs?
Our Vortex Tubes are available in 2 sizes (Small and Medium). Each Vortex Tube is constructed of stainless steel. The wear resistance of stainless steel, as well as its resistance to corrosion and oxidation, assures that STREAMTEK™ Corp., Vortex Tubes will provide years of reliable, maintenance free-operation.





Vortex Tubes 7500 Series: Optimize airflow and temperature drop to produce maximum cooling power.
Size
Model No.
Material
Small
Stainless 303
Small
Stainless 303
Small
Stainless 303
 
Medium
Stainless 303
Medium
Stainless 303
Medium
Stainless 303
Medium
Stainless 303
Medium
Stainless 303

Vortex Tubes 7700 Series: Optimize airflow and temperature drop to produce maximum cooling power.
Size
Model No.
Material
Small
Stainless 303
Small
Stainless 303
Small
Stainless 303
 
Medium
Stainless 303
Medium
Stainless 303
Medium
Stainless 303
Medium
Stainless 303
Medium
Stainless 303

 


Which Vortex Tube will best suit my needs?

Our Vortex Tubes are available in 2 sizes (Small and Medium). Each Vortex Tube is constructed of stainless steel. The wear resistance of stainless steel, as well as its resistance to corrosion and oxidation, assures that STREAMTEK™ Corp., Vortex Tubes will provide years of reliable, maintenance free-operation.


7500 Series Vortex Tube Specifications

The 7500 series Vortex Tubes are used in most industrial applications, such as electrical control panel cooling, tool cooling, and parts cooling. These Vortex Tubes optimize airflow and temperature drop to produce maximum cooling power or Btu/hr. (Kcal/hr.).

Size
Model No.
Air Consumption
BTU/Hr. @ 100 PSIG
Kcal / Hr. @ 6.9
Small 7502 2 SCFM (57 SLPM) 145 BTU/Hr. 37
Small 7504 4 SCFM (113 SLPM) 275 BTU/Hr. 69
Small
7508
8 SCFM (227 SLPM)
560 BTU/Hr.
141
Medium
7510
10 SCFM (283 SLPM)
700 BTU/Hr.
176
Medium
7515
15 SCFM (425 SLPM)
1100 BTU/Hr.
277
Medium
7525
25 SCFM (708 SLPM)
1800 BTU/Hr.
454
Medium
7530
30 SCFM (850 SLPM)
2060 BTU/Hr.
519
Medium
7540
40 SCFM (1133 SLPM)
2800 BTU/Hr.
706



7700 Series Vortex Tube Specifications

The 7700 series Vortex Tubes are used in applications which require extreme cold termperatures such as circuit board testing, and lab sampling cooling. These Vortex Tubes provide the lowest cold air temperatures, but at a low cold airflow (when less than a 50% cold fraction is used). The 7700 services Vortex Tubes should be only used when temperatures below 0º (-18ºC).

Size
Model No.
Air Consumption
BTU/Hr. @ 100 PSIG
Kcal/Hr. @ 6.9 BAR
Small
7702
2 SCFM (57 SLPM)
--
--
Small
7704
4 SCFM (113 SLPM)
--
--
Small
7708
8 SCFM (227 SLPM)
--
--
Medium
7710
10 SCFM (283 SLPM)
--
--
Medium
7715
15 SCFM (425 SLPM)
--
--
Medium
7725
25 SCFM (708 SLPM)
--
--
Medium
7730
30 SCFM (850 SLPM)
--
--
Medium
7740
40 SCFM (1133 SLPM)
--
--



Other Factors

Inlet Air Temperature
The Streamtek Vortex Tube will provide a temperature drop from the temperature of the compressed air supply.

Back Pressure
A low back pressure, up to 2 PSIG (.1 BAR), will not affect the performance of the Streamtek Vortex Tube. Anything over this will have a performance degration of ~ 5ºF (2.8ºC).

Filtration
Filtration to maintain clean air is necessary at a rate of 25 microns or less. Streamtek filters contain a 5 micron element and are properly sized for airflow.

Noise/Muffling
Both Small and Medium Vortex Tubes can be quite noisey if unducted. Streamtek offers mufflters for both cold and hot air discharge. If the cold air is ducted, muffling is not usually required.




Vortex Tube Specifications

PSIG
Cold Faction
10%
20%
30%
40%
50%
60%
70%
80%
90%
20
63F | 35C
62F | 34C
60F | 33C
56F | 31C
51F | 28C
44F | 24C
36F | 20C
28F | 15C
17F | 9C
7F | 4C
15F | 8C
25F | 14C
36F | 20C
50F | 28C
64F | 36C
83F | 46C
107F | 59C
148F | 82C
                 
40
91F | 51C
88F | 49C
85F | 47C
80F | 44C
73F | 41C
63F | 35C
52F | 28C
38F | 21C
26F | 14C
9F | 5C
21F | 11C
35F | 19C
52F | 29C
71F | 39C
92F | 51C
117F | 65C
147F | 82C
220F | 122C
                   
60
107F | 59C
104F | 58C
100F | 56C
93F | 52C
84F | 47C
73F | 41C
60F | 33C
45F | 25C
29F | 16C
10F | 6C
24F | 13C
40F | 22C
59F | 33C
80F | 44C
104F | 58C
132F | 73C
168F | 93C
236F | 131C
                   
80
119F | 66C
115F | 64C
110F | 61C
102F | 57C
92F | 51C
80F | 44C
66F | 36C
49F | 27C
31F | 17C
11F | 7C
25F | 14C
43F | 24C
63F | 35C
86F | 48C
113F | 63C
143F | 79C
181F | 101C
249F | 138C
                   
100
127F | 71C
123F | 68C
118F | 66C
110F | 61C
99F | 55C
86F | 48C
71F | 39C
53F | 29C
33F | 18C
12F | 8C
26F | 14C
45F | 25C
67F | 37C
91F | 51C
119F | 66C
151F | 84C
192F | 107C
252F | 140C
                   
120
133F | 74C 129F | 72C 124F | 69C 116F | 64C 104F | 58C 91F | 50C 74F | 41C 55F | 31C 34F | 19C
13F | 8C 27F | 14C 46F | 26C 69F | 38C 94F | 52C 123F | 68C 156F | 87C 195F | 108C 257F | 142C

    The percentage of cold air produced versus total filtered compressed air consumed by vortex tube.
    Pounds per Square Inch Gauge
    Drop in temperature.
    Rise in temperature.



Frequently Asked Questions



1. Can the Vortex Tube withstand back-pressure on the cold exhaust?
The performance is negatively impacted with back-pressure on the cold end exhaust. A Back-pressure of 5 PSIG will change performance by approximately 5°F. A low pressure up to 2 PSIG will not affect performance.


2. How does the Vortex Tube work?
Compressed air is injected into the vortex tube, flows at a rate of up to 1,000,000 RPM towards the 'hot' end of the tube. Once this hot air reaches the end, a small amount is exhausted through a control valve. The rest of the air is forced backwards towards the other end and exits as 'cold' air.


3. What is the Vortex Tube?
Vortex Tubes are a product of STREAMTEK Corp. Using compressed air as their only power source, cold air is produced on one and hot air on the other. All this is done with no moving parts!
The cold air is typically used for spot cooling and refrigeration applications. The hot air can be used for spot heating applications, but the temperatures are not very high.


4. How long has the Vortex Tube been around?
The vortex tube was invented in 1933 by French physicist Georges J. Ranque and German physicist Rudolf Hilsch improved the design and published a widely read paper in 1947 on the device, which he called a Wirbelrohr (literally, whirl pipe).
The Vortex Tube has been known as the “Hilsch Tube”, the “Ranque Vortex Tube”, the “Maxwells’s Demon, and the “Ranque-Hilsh Tube”. It’s a reliable, simple and low cost answer to various spot cooling problems within industrial plants.


5. Which Vortex Tube should I use?
STREAMTEK offers Small and Medium sized Vortex Tubes, each with a wide variety of cooling capacities. Vortex Tube Generator Kits allow you to experiment with a variety of temperatures and air flows. We recommend you talk to a STREAMTEK Application Engineer, as they can aid you in selecting the appropriate Vortex Tube for your application.


6. Is there anything in the Vortex Tube that can wear out or need replacing?
No. There are no moving parts, it will never wear out. They may need cleaning from time to time if there is contamination within the air supply. The Vortex Tube is constructed of type 303 stainless steel, brass generators, and a brass control valve.


7. Where can the Vortex Tube be used?
The Vortex Tube is typically used in spot cooling applications. Use it to cool, molds, machining operations, hot parts, electronics, etc. The hot end could be used to heat glues, shrink wraps, or for drying parts.


8. Can I use a Vortex Tube to cool my electrical enclosure instead of the Cabinet Panel Cooler?
Yes, however there are clear-cut advantages to using the STREAMTEK Cabinet Panel Cooler for this application.
  • Cabinet Panel Coolers have a pressure release valve to allow warm air from the electrical enclosure to escape the cabinet.
  • Cabinet Panel Coolers have been fine tuned to achieve maximum refrigeration; this cannot be adjusted. Vortex Tubes on the other hand can be adjusted by the user, leaving them open to poor operation and miss-adjustment.
  • Cabinet Panel Coolers have been engineered to reduce noise levels drastically from that of the sole Vortex Tube.


9. Can I connect the cold end of a Vortex Tube to an Air Amplifier or Air Knife?
No. The Air Amplifier and Air Knife would both restrict the air flow of the Vortex Tube to the point where back-pressure would limit the cooling capacity of the Vortex Tube. The cold end of the Vortex Tube should not be subjected to a backpressure in excess of 5 PSIG.




Note: Animation may take up to 10 seconds to load.

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player


APPLICATIONS

ADVANTAGES
  • Cooling electronic controls
  • Cooling machining operations
  • Setting hot melts
  • Cooling soldered parts
  • Cooling gas samples
  • Electronic component cooling
  • Cooling heat seals.
  • Cooling environmental chambers
  • Maintenance free (No moving parts)
  • Cools without costly electricity or refrigerants
  • Reliable, compact and lightweight
  • Low cost application
  • Durable - Stainless Steel
  • Adjustable temperature
  • Instant cold air










SMALL VORTEX TUBE  
Without muffler(s) Assembled with muffler(s)
vortextubesmall vortextubesmallmufflers

 

MEDIUM VORTEX TUBE  
Without muffler(s)  
vortextubemedium  
Assembled with muffler(s)  
vortextubemediumufflers  

 


Vortex Tube Accessories

Silencing Mufflers: Cold & Hot End
Model No.
Description
Cold End Muffler for Small Vortex Tube
Cold End Muffler for Medium Vortex Tube
Hot End Muffler for Small & Medium Vortex Tube


Generators: 7500 Series - The 7500 Series Generators optimize airflow and temperature drop to produce maximum cooling power.
Model No.
Description
2 SCFM SmallGenerator - Maximum Cooling
4 SCFM Small Generator- Maximum Cooling
8 SCFM Small Generator - Maximum Cooling
   
10 SCFM Medium Generator - Maximum Cooling
15 SCFM Medium Generator - Maximum Cooling
25 SCFM Medium Generator - Maximum Cooling
30 SCFM Medium Generator - Maximum Cooling
40 SCFM Medium Generator - Maximum Cooling


Generators: 7700 Series - The 7700 Series Generators provide the lowest cold air temperatures, but at a lower cold airflow.
Model No.
Description
2 SCFM Small Generator - Maximum Low Temperature
4 SCFM Small Generator - Maximum Low Temperature
8 SCFM Small Generator - Maximum Low Temperature
   
10 SCFM Medium Generator - Maximum Low Temperature
15 SCFM Medium Generator - Maximum Low Temperature
25 SCFM Medium Generator - Maximum Low Temperature
30 SCFM Medium Generator - Maximum Low Temperature
40 SCFM Medium Generator - Maximum Low Temperature


Generators: Kits
Model No.
Description
Small Vortex Tube Generator Kit (ALL Generators included)
Medium Vortex Tube Generator Kit (ALL Generators included)


Vortex Tube: Kits - Includes a vortex tube, ALL Generators, Cold End Muffler, and 1/4" NPT Auto Drain Filter.
Model No.
Description
Small Vortex Tube Kit
Medium Vortex Tube Kit








General Accessories

Filter Separators:
Model No.
Description
1/4" NPT, 5 micron, 27 SCFM , Metal Bowl, Auto Drain Filter
1/4" NPT, 5 micron, 43 SCFM, Metal Bowl, Auto Drain Filter
3/8" NPT, 5 micron, 75 SCFM, Metal Bowl, Auto Drain Filter
1/2" NPT, 5 micron, 100 SCFM, Metal Bowl, Auto Drain Filter
3/4" NPT, 5 micron, 230 SCFM , Metal Bowl, Auto Drain Filter
1" NPT, 5 micron, 300 SCFM, Auto Drain Filter


Pressure Regulators:
Model No.
Description
1/4" NPT, 49 SCFM, Pressure Regulator with Gauge
3/8" NPT, 84 SCFM, Pressure Regulator with Gauge
1/2" NPT, 84 SCFM, Pressure Regulator with Gauge
3/4" NPT, 220 SCFM, Pressure Regulator with Gauge
Gauge Only, 1/4" NPT, 15-150 PSIG.


Oil Removal Filters:
Model No.
Description
1/4" NPT, .03 sub micron filter, 24 SCFM, Auto Drain Filter
3/8" NPT, .03 sub micron filter, 37 SCFM, Auto Drain Filter
3/4" NPT, .03 sub micron filter, 50-180 SCFM, Auto Drain Fil.


Valves:
Model No.
Description
1/4" NPT, Manual Valve
3/8" NPT, Manual Valve
1/2" NPT, Manual Valve
1" NPT, Manual Valve


Compressed Air Hose:
Model No.
Description
3/8" ID Compressed Air Hose, 10' (305cm) Long -
1/4" NPTM x 1/4" NPTF
3/8" ID Compressed Air Hose, 15' (457cm) Long -
1/4" NPTM x 1/4" NPTF
3/8" ID Compressed Air Hose, 20' (610cm) Long -
1/4" NPTM x 1/4" NPTF
3/8" ID Compressed Air Hose, 30' (914cm) Long -
1/4" NPTM x 1/4" NPTF
3/8" ID Compressed Air Hose, 40' (1219cm) Long -
1/4" NPTM x 1/4" NPTF
3/8" ID Compressed Air Hose, 50' (1524cm) Long -
1/4" NPTM x 1/4" NPTF


 


Back to Top of Page

servicing the Canadian provinces of Newfoundland, Nova Scotia, New Brunswick, Prince Edward Island, Quebec, Ontario, Manitoba, Saskatchewan, Alberta ,British Columbia and the states of Alabama, Alaska, Arizona, Arkansas, California, Colorado, Connecticut, Delaware, Florida, Georgia, Hawaii, Idaho, Illinois, Indiana, Iowa, Kansas, Kentucky, Louisiana, Maine, Maryland, Massachusetts, Michigan, Minnesota, Mississippi, Missouri, Montana, Nebraska, Nevada, New Hampshire, New Jersey, New Mexico, New York, North Carolina, North Dakota, Ohio, Oklahoma, Oregon, Pennsylvania, Rhode Island, South Carolina, South Dakota, Tennessee, Texas, Utah, Vermont, Virginia, Washington, West Virginia, Wisconsin,Wyoming We can ship via UPS to Afghanistan , Aland Islands , Albania , Algeria , American Samoa , Andorra , Angola , Anguilla , Antigua & Barbuda , Argentina , Armenia , Aruba , Australia , Austria , Azerbaijan , Azores , Bahamas , Bahrain , Bangladesh , Barbados , Belarus , Belgium , Belize , Benin , Bermuda , Bhutan , Bolivia , Bonaire , Bosnia , Botswana , Brazil , British Virgin Isles , Brunei , Bulgaria , Burkina Faso , Burundi , Cambodia , Cameroon , Canada , Canary Islands , Cape Verde , Cayman Islands , Central African Republic , Chad , Chile , China , Colombia , Comoros , Congo , Cook Islands , Costa Rica , Croatia , Curacao , Cyprus , Czech Republic , Democratic Republic of Congo , Denmark , Djibouti , Dominica , Dominican Republic , Ecuador , Egypt , El Salvador , England , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Faeroe Islands , Fiji , Finland , France , French Guiana , French Polynesia , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Greenland , Grenada , Guadeloupe , Guam , Guatemala , Guernsey , Guinea , Guinea-Bissau , Guyana , Haiti , Holland , Honduras , Hong Kong , Hungary , Iceland , India , Indonesia , Iraq , Ireland , Israel , Italy , Ivory Coast , Jamaica , Japan , Jersey , Jordan , Kazakhstan , Kenya , Kiribati , Kosrae , Kuwait , Kyrgyzstan , Laos , Latvia , Lebanon , Lesotho , Liberia , Libya , Liechtenstein , Lithuania , Luxembourg , Macau , Macedonia (Fyrom) , Madagascar , Madeira , Malawi , Malaysia , Maldives , Mali , Malta , Marshall Islands , Martinique , Mauritania , Mauritius , Mayotte , Mexico , Micronesia , Moldova , Monaco , Mongolia , Montenegro , Montserrat , Morocco , Mozambique , N. Mariana Islands , Namibia , Nepal , Netherlands , Netherlands Antilles , New Caledonia , New Zealand , Nicaragua , Niger , Nigeria , Norfolk Island , Northern Ireland , Norway , Oman , Pakistan , Palau , Panama , Papua New Guinea , Paraguay , Peru , Philippines , Poland , Ponape , Portugal , Puerto Rico , Qatar , Reunion , Romania , Rota , Russia , Rwanda , Saba , Saipan , San Marino , Saudi Arabia , Scotland , Senegal , Serbia , Seychelles , Sierra Leone , Singapore , Slovakia , Slovenia , Solomon Islands , South Africa , South Korea , Spain , Sri Lanka , St. Barthelemy , St. Christopher , St. Croix , St. Eustatius , St. John , St. Kitts & Nevis , St. Lucia , St. Maarten , St. Martin , St. Thomas , St. Vincent/Grenadines , Suriname , Swaziland , Sweden , Switzerland , Syria , Tahiti , Taiwan , Tajikistan , Tanzania , Thailand , Timor Leste , Tinian , Togo , Tonga , Tortola , Trinidad & Tobago , Truk , Tunisia , Turkey , Turkmenistan , Turks & Caicos Islands , Tuvalu , Uganda , Ukraine , Union Island , United Arab Emirates , United Kingdom , United States , Uruguay, US Virgin Islands , Uzbekistan , Vanatu , Vatican City State , Venezuela , Vietnam , Virgin Gorda , Wales , Wallia & Futuna Islands , Western Samoa , Yap , Yemen , Zambia , Zimbabwe