TI-25S
Ultrasonic Wall Thickness Gauge |
|
The
TI-25S is ideal for the person that tests a few different materials
regularly. The TI-25S contains 8 velocities of the most common
materials (refer to complete list of Materials below) and two
velocities that the user can set using a simple software program.
The tool's backlit display is easy to read, even in dim light,
and the unit operates for up to 200 hours on a single set of
batteries.
The TI-25S comes complete, ready to use, and is protected
by our 5 year limited warranty.
Velocity Settings
The TI-25S has 8 preset velocities and 2 custom velocities allowing
the user to customize it for specific applications, or to tune
the calibration to be optimized for a specific type of material.
Each time the "MATL Key" is pressed the velocity will
toggle from one to the next in a circular pattern. The list of
preset velocities are as follows:
- 1. Aluminum 2024 (0.251 in/µs )
- 2. Stainless Steel 303(0.223 in/µs )
- 3. Steel4340 (0.233 in/µs)
- 4. Cast Iron (0.179 in/µs )
- 5. Plexiglass (0.106 in/µs )
- 6. PVC (0.094 in/µs)
- 7. Polystyrene (0.092 in/µs)
- 8. Polyurethane (0.070 in/µs)
- 9. Custom 1
- 10. Custom 2
Note: If the Custom 1 & 2 are needed, they are set using
the PC software (free) & downloaded to gauge using the data
cable (optional, p/n N-306-0010) |

Features
Multi-function
4.5 digit liquid crystal display with 0.500 inch numerals, backlit
for use in poor light conditions. |
Measurements
displayed in inches, inches/microsecond, millimeters, and meters/second. |
Measures
from 0.025 to 19.999 inches (0.63 to 199.99 millimeters) switch
to select English or metric units. |
|
Four
readings per second for single point measurements. |
8
pre-set velocities and 2 custom velocities |
Ability
to change between velocities without the use of computer software |
|

10
User-Selected Material Types
Each time the "Matl" key is pressed, the material type
(calibration setting of the acoustic velocity) changes from one
type to the other. The abbreviations, description and sequence
is shown below.
*Note: If the Custom 1 & 2 are needed, they are set using
the PC software (free) & downloaded to gauge using the data
cable (optional, p/n N-306-0010) |

Typical
Applications


Complete
Kit
|
|
|
The TI-25S is supplied as a complete kit with the gauge, probe,
4 oz. bottle of coupling fluid, 2 AA batteries, PC-based Software,
NIST-Traceable Calibration Certificate, and Operating Instruction
Manual - all in a foam-fitted carrying case.
DATA CABLE MUST BE ORDERED SEPARATELY TO PROGRAM USER #1 and
#2 CUSTOM VELOCITIES |
 |

Measuring
Limits
|
Minimum Radius for Convex Surfaces |
0.350" (8.89 mm) |
|
Minimum Radius for Concave Surfaces |
3" (76.2 mm) |
|
Minimum Headroom |
1" (25.0 mm) |
|
Minimum Sample Diameter |
0.150" (3.8 mm) |
|
Minimum Substrate Thickness - F |
na |
|
Minimum Substrate Thickness - NFe |
na |

Related
Products
|
|
|
NIST-Traceable Steel Test Block
3 Sizes Available |
|
|
Precision
Machined and Finished
Includes
NIST-Traceable Report and Test Data
|
|
|
|
|
___________________________________________ |
|
|
|
Uncertified Steel Test Block
For Ultrasonic Gauges |
|
|
For
convenient confirmation of thickness gauge calibration
|
|
|
|
|
___________________________________________ |
|
|
|
TICC-M
Protective Holder for Ultrasonic Gauges |
|
|
Constructed
from heavy duty Cordura Nylon
|
|
|
|
|
___________________________________________ |
|
|
|
CF12
Coupling Fluid |
|
|
Used
to create an ultrasonic coupling between the probe and material
to be measured
12oz
Bottle
|
|
|
|
|
___________________________________________ |
|
|
|
V-Block
Transducer Holder |
|
|
The
V-Block transducer holder offers the operator greater control
and repeatabily when measuring on pipes and other curved areas.
|
|
|
|
|
___________________________________________ |
|
|
|
DataComm
Software |
|
|
Free
data acquisition software
|
|
|
|
|
___________________________________________ |
|
|
|
N-306-0010
Transfer Cable |
|
|
|
|
|

Specifications
|
Measuring Range |
0.025 to 19.999 inches
0.63 to 199.99 millimeters
depends on material and probe used |
|
Range in Steel |
0.025-6.00" (0.60-150.0 mm) |
|
Resolution |
.001" (0.01 mm) |
|
Velocity Range |
.0492 to .3937 in/µs
1250 to 10,000 meters/sec |
|
Dimensions |
2.5 W x 4.75 H x 1.25 D inches |
|
Display |
4½ - Digit, 0.5" Backlit LCD |
|
Probe |
1/4", 7.5 MHz, actual wearface is 3/8" (10 mm)
Probe P/N: T-102-3300 |
|
Cable |
4 ft. (1.2 m) waterproof cable with non-polarized, quick-disconnect
connectors. Optional lengths up to 50 ft. (15 m). |
|
Temp. Limits |
Ambient: -20 to 120° F (-30 to 50° C)
Material: -0 to 200° F (-20 to 100° C
Special high temperature probes are optionally available. |
|
Battery Type |
Two 1.5V alkaline or 1.2V NiCad AA cells. |
|
Battery Life |
Typically operates for 200 hours on alkaline and 130 hours on
NiCad. |
|
Weight |
10 ounces (283 g) |
|
Accessories Included |
Probe/cable assembly. 4 oz. bottle of coupling fluid, NIST Calibration
Certificate, 2 AA batteries, operating instructions, hard-plastic
carrying case. |
|
Warranty |
Gauge: 5 Years
Probes: 90 Days |

Download

|
Item |
Description |
|
CHE.TI-25S |
TI-25S Complete Kit includes Gauge, transducer, couplant, manual,
software in carrying case |
|
Accessories |
|
CHE.TICC-M |
Protective Holder for TI-25S |
|
CHE.CF-12 |
Coupling Fluid - 12oz |
|
CHE.V-Block |
V-Block Transducer Holder |
|
CHE.T-102-2000 |
Spare / Replacement Probe for TI-25S |
|
CHE.DATACOMM |
PC Program to download Custom #1 & Custom #2 calibrations
to TI-25S (N-306-0010 cable must be ordered) |
|
CHE.N-306-0010 |
Data Cable to connect TI-25S to PC |
|
CHE.T-212-2001 |
1/4" - 5 MHz Hi Temp - 900 °F / 500 °C Dual Microdot
connectors, top-in |
|